The Kimya TPC -91A 3D filament belongs to the thermoplastic copolyester family: is an elastomer. TPC is an elastomer obtained by copolymerization of two types of monomers: an ester (a rigid segment) and an ether (a flexible segment). It offers chemical and impact resistance. It provides Shore hardness of 91 A. It can be used to produce flexible parts. The Kimya TPC-91A 3D filament can be used in industrial applications in sectors such as electronics, textiles, roofing, etc., and in decorative and leisure 3D printing applications. It offers the following properties:

  • Flexibility
  • Easy to print
  • Elongation > 500%
  • Complies with the REACH regulation and the RoHS directive

Store away from light, humidity and heat to maintain the properties of the product.

PE1006TQ

FILAMENT PROPERTIES

 

PROPERTIESTEST METHODSVALUES
Diameter INS-6712 1.75 ± 0.1 mm
2.85 ± 0.1 mm
Density ISO 1183-1 1.22 g/cm3
Moisture rate INS-6711 < 0.5 %
Melt flow index (MFI) ISO 1133-1 18 - 20 g/10min
Melting Temperature (Tm) ISO 11357-1 DSC (10°C/min – 20-220°C) 159 °C

 

PRINT PARAMETERS AND SPECIMENS DIMENSIONS

 

PRINTING DIRECTIONXY
Printing Speed 44 mm/s
Infill 100% - rectilinear
Infill Angle 45°/-45°
Nozzle Temperature 260°C
Bed T° 60°C

 

PRINTED SPECIMENS PROPERTIES

 

PROPERTIESTEST METHODSVALUES
MECHANICAL PROPERTIES Tensile modulus ISO 37/2/500 67 MPa
Tensile Strength ISO 37/2/500 17.7 MPa
Tensile strain at strength ISO 37/2/500 > 500 %
Tensile Stress at Break ISO 37/2/500 17.5 MPa
Tensile strain at break (type A) ISO 37/2/500 > 500 %
Flexural modulus ISO 178 66 MPa
Flexural stress at conventional deflection (3,5% strain)* ISO 178 2.6 MPa
Charpy impact resistance ISO 179-1/1eA No Break
Shore Hardness ISO 868 91A

 

Note 1 *According to ISO 178, end of the test at 5% deformation even if there is no specimen break.
Note 2 The data should be considered as indicative values - Properties can be influenced by production conditions.

Created on 01/07/2019 - Revised on 13/03/2023.